Hans, 

As peculiar as it sounds, yes it can be done and I have seen such a product. Of 
course you need to get a special power cord through the agency, with a two 
prong cap at one end, two conductors, and a three contact cord connector body. 

Gabriel Roy
Hughes network Systems
MD
(64 left)


------------------------------------- snip ---------------------------------

Fellow professionals;

Is there anything in the EN60950 regulations re: LVD that would prevent me 
from using a IEC three prong receptacle in my product connected to a 
special power cord with only two wires and to a class 0 plug (two prong for 
Europe) and the mating IEC 320 connector at the other end? (assume that my 
product is designed to be double insulated).

Best Regards

Hans
 