From:                   Gary McInturff <[email protected]>
To:                     "Robert F. Martin ITS/QS-Box" <[email protected]>,
        Randall Flinders
        <[email protected]>,
        "'emc-pstc'" <[email protected]>
Subject:                RE: Lab qualification
Date sent:              Tue, 6 Oct 1998 16:09:41 -0700 
Send reply to:          Gary McInturff <[email protected]>

> Yeah, I second that. I try to believe in as little confirmation as
> possible. Extended stacks of paper don't verify anything. For the EMC
> stuff I think that you really want to deal with labs that have NIST
> approval through NVLAP or A2LA. Among other things if you don't need an
> FCC ID you can ship your product as soon as you have the report rather
> than wait for the 6 weeks of FCC time. These labs are also the only ones
> that are going to be covered in the MRA's with Europe etc

<snip>

Just a reminder, All - 

Canadian labs which are accredited by the Standards Council of 
Canada also enjoy the same status as A2LA and NVLAP labs with 
respect to FCC DoC rules.  The accreditation standard is also ISO 
Guide 25. The Canadian - EU MRA is signed and in the 
implementation phase, by the way...

I would add one additional suggestion to all of this discussion of lab 
qualification:

Many labs, although they may be technically competent, and have 
the quality systems and controls to carry out accurate work, fail to 
properly showcase their work in the reports which they produce for 
their clients.  Agency personnel (FCC, IC, etc) HAVE 
COMMENTED TO ME ON THIS - understand that a poorly 
prepared report reflects poorly on you as a manufacturer.  

This is a mystery to us, as we see our reports as being the 
tangible output of our work - test, certifcation or research.  Ask to 
be shown a sample report!  And beware of offers of "free" or 
"cheap" reports - you will often get what you pay for.  It takes 
proper time and attention to carry out analysis of data and to 
prepare reports and submissions.

Regards,
Kathy 




Kathy MacLean
President 
APREL Laboratories
-Research-Consulting-Training-Certification Testing-
-Specialists in Electromagnetics, Acoustics, 
Wireless Telecommunications, and SAR-
51 Spectrum Way, Nepean, Ontario, Canada K2R 1E6
(613) 820-2730  (613) 820-4161(fax) 
http://www.aprel.com

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to