Gary (and others): I have the same recollection vis-a-vis the VDE
COnducted emisions requirements.
Thank you
Charles Grasso
(Capn Hook)

> ----------
> From:         Gary McInturff[SMTP:[email protected]]
> Sent:         Friday, December 04, 1998 2:12 PM
> To:   [email protected]; Muriel Bittencourt de Liz
> Cc:   [email protected]
> Subject:      RE: Doubt on LISN utilization
> 
> I have a recollection that at one point VDE required the choke in the
> ground
> line of the LISN. Vaguely remembered it had to do with extremely long
> build
> grounds as in high rise buildings etc, or the possibility of no ground
> wire.
> I seem to remember some connection with shielded power cables as well.
> Anyone else have any recollection of this?
> Gary McInturff
> 
>       -----Original Message-----
>       From:   [email protected] [SMTP:[email protected]]
>       Sent:   Friday, December 04, 1998 9:26 AM
>       To:     Muriel Bittencourt de Liz
>       Cc:     [email protected]
>       Subject:        Re: Doubt on LISN utilization
> 
> 
> 
>       It is possible to get noise induced on all cabling at the same time.
> In
>       this case it will be also be present on the ground lead. To reduce
> this
>       noise "ground chokes" are used. It is also extra attenuation for
> common
>       mode currents.
> 
>       Bob Heller
>       Senior EMC Engineer
>       3M Company
>       =============================================================
> 
> 
>                                                                         
>        (Embedded                                                        
>        image moved   Muriel Bittencourt de Liz <[email protected]>    
>        to file:      12/03/98 10:59 AM                                  
>        pic11332.pcx)                                                    
>                                                                         
> 
> 
> 
>       Please respond to Muriel Bittencourt de Liz <[email protected]>
> 
> 
>       To:  Lista de EMC da IEEE <[email protected]>
>       cc:   (bcc: Robert E. Heller/US-Corporate/3M/US)
>       Subject:  Doubt on LISN utilization
> 
> 
> 
> 
>       Hello All,
> 
>       I have a LISN from EMCO and it has a "Ground Choke". What's the goal
> of
>       this Ground Choke? Is it really needed in the conducted
> measurements?
>       Could somebody make this clear to me?
> 
>       Thanks in advance
> 
>       Muriel
> 
>       --
> 
>       ==================================================
> 
>        Muriel Bittencourt de Liz
>        INEP - Instituto de Eletronica de Potencia
>        Universidade Federal de Santa Catarina
>        Caixa Postal - 5119
>        88.040-970 - Florianopolis - SC - BRASIL
>        Phone: +55.48.331.9204 - Fax: +55.48.234.5422
>        e-mail:   [email protected]
>        Homepage:   http://www.inep.ufsc.br
> 
>       ==================================================
> 
>       ---------
>       This message is coming from the emc-pstc discussion list.
>       To cancel your subscription, send mail to [email protected]
>       with the single line: "unsubscribe emc-pstc" (without the
>       quotes).  For help, send mail to [email protected],
>       [email protected], [email protected], or
>       [email protected] (the list administrators).
> 
>        << File: pic11332.pcx >> 
> 
> ---------
> This message is coming from the emc-pstc discussion list.
> To cancel your subscription, send mail to [email protected]
> with the single line: "unsubscribe emc-pstc" (without the
> quotes).  For help, send mail to [email protected],
> [email protected], [email protected], or
> [email protected] (the list administrators).
> 

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to