David Clark pointed out an error in my posting.  
I SHOULD have said:



According to the OSM/EE list of decisions dated
9/99...

Varistors between the mains and the protective
earth cannot be accepted by the following 
countries:

    Pluggable equipment, Type A:  Austria, Belgium,
    Denmark, Finland, Norway, Sweden, United Kingdom.


Varistors between the mains and the protective 
earth can be accepted by the following countries:

    Permanently connected equipment connected to 
    Protective Earth:  All countries.


Sorry for any confusion.


Best regards,
Rich




-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              [email protected]
     Michael Garretson:        [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]

Reply via email to