Hi Ron:
According to the OSM/EE list of decisions dated
9/99...
Varistors between the mains and the protective
earth cannot be accepted by the following
countries:
Pluggable equipment, Type A: Austria, Belgium,
Denmark, Finland, Norway, Sweden, United Kingdom.
Permanently connected equipment connected to
Protective Earth: All countries.
There is no specific mention of concern for possible
increase in leakage current.
I'll send the OSM paper in a separate message.
Best regards,
Rich
-------------------------------------------