Not sure how far this will fly, 
but I'm definitely going to find out. 

Thanks. 

- Doug 

mike harris wrote:
> 
> Hi Doug,
> 
> I believe there is another option (which may or may not be palatable) - You
> can ask your NRTL to strap out (bypass) the fuse and conduct whatever tests
> they like & if there is no fire or shock danger they must ignore the fuse
> rating entirely. The down side of this is the cost & time of the additional
> testing.
> 
> Mike Harris/Teccom

-------------------------------------------
This message is from the IEEE EMC Society Product Safety