Not sure how far this will fly,
but I'm definitely going to find out.
Thanks.
- Doug
mike harris wrote:
>
> Hi Doug,
>
> I believe there is another option (which may or may not be palatable) - You
> can ask your NRTL to strap out (bypass) the fuse and conduct whatever tests
> they like & if there is no fire or shock danger they must ignore the fuse
> rating entirely. The down side of this is the cost & time of the additional
> testing.
>
> Mike Harris/Teccom
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Jim Bacher: [email protected]
Michael Garretson: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]