The product or family standard that references this standard may require
different a higher  number of applications. Abide by what your product of
family standard specifies. If it is silent, then apply per the base
standard.

Richard Woods

        ----------
        From:  [email protected] [SMTP:[email protected]]
        Sent:  Monday, January 17, 2000 5:41 AM
        To:  [email protected]
        Subject:  EN 61000-4-2


        Dear all

        I'm writing on a internal testprocedure for our products, and have
now come to
        EN 61000-4-2 ESD. What confuse me is that the standard (as I read
it) only
        refere to 10 discharges at each point (and each polarity), but I
have been told
        from several different persons that the right number is 50 at each
points (but
        without any reference to any standard).

        Do anynoe know what the right number is and where I can find it

        Best regards,

        Mr. Kim Boll Jensen
        i-data international
        Denmark



        ---------