> From: peter merguerian > Sent: Tuesday, January 06, 2004 9:10 PM > > 1. Telecom Cables must meet UL1863.
It is important to note that UL1863 applies to terminated cable assemblies, such as handset cords, line cords and the like. It does not apply to the raw cable. UL444, Standard for Communications Cable is used for that purpose. Regards, Peter L. Tarver, PE [email protected] This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ieee-pses.org/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc