http://www.ieee-pses.org/symposium http://www.emc2004.org/
Hello all UL60950, subclause 2.8.6 requires that an interlock override system shall "reset automatically to normal operation when servicing is complete, or prevent normal operation unless the service personnel have carried out restoration" I believe this means: "reset automatically to normal INTERLOCK SYSTEM operation when servicing is complete, or prevent normal MACHINE operation unless the service personnel have carried out restoration OF THE INTERLOCK SYSTEM" I would like to get approvals to this, or other opinions Thanks ! Israel Yeshurun This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. IEEE PSES Main Website: http://www.ieee-pses.org/ To post a message send your e-mail to [email protected] Instructions for use of the list server: http://listserv.ieee.org/listserv/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc