Hi EMI Gurus, I need to troubleshoot a logic failure which occurs when 16 kV ESD pulses are applied to the PCB. Is there a reliable way to attach the oscilloscope probe to the failing device while ESD gun is being fired elsewhere on the PCB. Will it help if I use a differential probe.
Thanks for the help. Regards, Ravinder Ajmani Server PCB Development Hitachi Global Storage Technologies Email: [email protected] - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc