In message <[email protected]>, dated Thu, 16 Feb 2006, 
[email protected] writes
>I Need help to decide on FUSE value for ITE equipment. We are using 
>power suppy which has UL rated 20A fuse and C14 inlet, the question I 
>have is it OK to ship this product to Europe with power cords which use 
>C13 connector?

If it has a 20 A fuse, that exceeds the current rating of normal 
wall-sockets, which is 13 A in UK and 16 A in most other European 
countries. Of course, there are industrial outlets that have higher 
ratings, but I think you have to go to 32 A as the next step (assuming 
this is all at 230 V). I don't recognize the codes 'C13' and 'C14'.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
2006 is YMMVI- Your mileage may vary immoderately.

John Woodgate

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc