Hi Daniel and the group,
When I hear of modern exposure limits I think back to my earlier days.
When I was in the 9th grade of junior high school, I built a Tesla
coil powered by a pair of 811A transmitting tubes (you could read a
book by the light these tubes produced) and using a 3B28 xenon gas
rectifier tube. About 600 watts of RF was produced by the tubes and
the main coil produced fields where I was standing of many thousands
of Volts per meter electric field. I played in that field trying
different experiments for many many hours. The resonant frequency of
the coils was about 300 kHz.
The device was a lot of fun. I could heat up screwdriver blades by
holding them in the primary coil with secondary removed. If I put a
six inch piece of bare wire about a foot from the primary coil with
secondary installed. I could jump a 1/2 inch continuous spark from the
short wire to my finger! The corona at the top of the coil would form
into something of a spark directed towards an approaching finger and
connect at about 4 inches away. A fluorescent tube would light up full
brilliance a few feet from the coil with no wires attached. Killed
every TV picture on the block. I was not popular with my neighbors.
The Tesla coil won first place at the science fair.
I am still here, although my friends say the hours with the Tesla coil
explains some things about me. :-)
Doug
Daniel Liang wrote:
> Dear all experts,
>
> Does anyone know the tables in the ICNIPR specification about the limits
> of the general or occupational exposure ( E-field, H-field and power
> density ), they are referred to what distance away from the EUT? Thanks.
>
> Regards,
>
> Daniel.
>
--
___ _ Doug Smith
\ / ) P.O. Box 1457
========= Los Gatos, CA 95031-1457
_ / \ / \ _ TEL/FAX: 408-356-4186/358-3799
/ /\ \ ] / /\ \ Mobile: 408-858-4528
| q-----( ) | o | Email: [email protected]
\ _ / ] \ _ / Web: http://www.dsmith.org
-
This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list. Website: http://www.ieee-pses.org/
To post a message to the list, send your e-mail to [email protected]
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas [email protected]
Mike Cantwell [email protected]
For policy questions, send mail to:
Jim Bacher: [email protected]
David Heald: [email protected]
All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email
______________________________________________________________________