In message <[email protected]>, dated Wed, 
18 Jul 2007, Brian O'Connell <[email protected]> writes:

>Your most sacred guidance is found in sections 4.3 and 11 of 60065, the 
>excerpts sayeth:

This is a case where you need to 'read between the lines'. See my other 
post.

Cases have been reported where replacement of a resistor by a 'better' 
(more durable under overload) product has made the product much less 
safe.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
There are benefits from being irrational - just ask the square root of 2.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-