Grace,
    Yes, Telecom ports is in effect as of August 2007. We upgraded our system
based upon a previous discussion last year that 8 wire ISNs are to be used on
unshielded ports regardless of the number of wires used. We purchased the
TESEQ (formerly Schaffner Test Systems) ISN. I also received in the last month
a flyer on an upgrade to the system to support CAT 6 Wiring when used.
Larry Stillings
Compliance Worldwide, Inc.

  _____  

From: Grace Lin [mailto:[email protected]] 
Sent: Wednesday, March 26, 2008 11:48 AM
To: [email protected]
Subject: Telecom Ports Requirements per EU


Dear Members,
 
Could you please comment the latest requirement on telecom port?  Is telecom
port measurement mandatory per EU at this time?  Section 5.2 of CISPR 22: 2005
with A1+A2 and EN 55022: 2006 lists limits of conducted common mode
(asymmetric mode) disturbance at telecommunication ports.
 
China has decided to postpone the telecom port requirement (as of early this
month).  BSMI (Taiwan) is discussing this requirement and has not mandated it.
 I believe VCCI (Japan) has not mandated it, either.
 
In addition, if you know any manufacturers and models for ISN for Category 5
and Category 6 Ethernet port, please share with me.
 
Thank you very much and look forward to your help.
 
Best regards,
Grace
- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc 

- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc 


Reply via email to