Forum members,

 

Thanks for your help to everyone you replied to my question.

 

Regards

 

Ian White

 

From: Ian White (UK) 
Sent: 24 August 2011 10:22
To: IEEE Forum ([email protected])
Subject: EN61000-4-2 questions

 

 

Forum members,

 

 

We are  testing a product which is made of metal and due to the size of it l
have a table top test set up very similar to that shown in Figure 4 of the
standard EN61000-4-2:2009.

 

The unit is sitting on insulation 0.5mm thick on the horizontal coupling
reference plane.

 

In service this product sits in a steam line and has hardwired earths
connected to earth for functional reasons,  I have connected these earths to
the horizontal coupling plane, is this correct ? The standard does not appear
to give any guidance on this matter, but it seems the only logical solution.

 

Thanks for your help.

 

 

Ian White