Good luck Jim…  We moved one two years ago and that pain is still fresh in
my mind.  The only advice I can offer on that is to label everything and take
plenty of notes/pictures.

 

While I won’t be moving a chamber anytime soon, we are trying to get
approval to replace the same, aging 856x stack.  If anyone cares to comment on
that online, I would be interested in any thoughts or recommendations as well.
 We’re also in the same situation of needing to go beyond 1GHz RE
measurements (also in a 3m SAC), so any comments on that topic would be
appreciated as well.

 

Thanks,

Chris

 

 

From: [email protected] [mailto:[email protected]] On Behalf Of
[email protected]
Sent: Monday, February 14, 2011 3:15 PM
To: [email protected]
Subject: Considering a consultant to help with semi-anechoic chamber
relocation and performance improvements

 


Hi everyone:  We are about to move (groan) and while this generally is a pain,
it provides the opportunity to fix a few problems along the way.  Our 3m SAC
is usable, and indeed gets fairly heavy use, but is not as good as I think it
could be, in a few ways:   

       - Our emissions measurement correlation to "real" labs is OK but could
be better, particularly on conducted emissions 

       - Our aging HP rack (the classic 856x series) is getting old and is
starting to be costly to maintain - time to switch?

       - We have always just had a manual turntable and would like to see
what's involved in going with a motorized turntable and controller 

       - We have aging cones, many with broken tips - maybe not an issue, but
maybe it is? 

       - We haven't researched what it would take to go past 1GHz with our RE
measurements, but we need to 

       - Etc. 

I think it would be worthwhile to have someone who is an expert in design and
troubleshooting of SAC's and EMC instrumentation come here, give us a
once-over, make recommendations for improvements that we could implement as
part of the move, and perhaps participate in the teardown and relocation of
the chamber (not as simple as it sounds) or recommend someone who could.  

If you are interested and qualified, or know someone who is, please reply to
me off-line at [email protected].  I would prefer somebody
at least somewhat local - we are in the Vancouver BC area. 

Thanks, 

Jim  
_______________________________________
_____________________________________________ 

Jim Eichner  |   Schneider Electric   |  Renewable Energies Business  |  
CANADA  |   Compliance Engineering Manager 
 Site: www.schneider-electric.com/renewable-energies
<http://www.schneider-electric.com/renewable-energies>   |   Address: 8999
Nelson Way, Burnaby, BC, V5A 4B5 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to