Yes, the mains is a hazard.  If the enclosure and insulation mitigate it 
adequately (I.e. tolerable risk), then no further action is necessary.

----- Reply message -----
From: "Richard Nute" <[email protected]>
List-Post: [email protected]
Date: Mon, Nov 1, 2010 6:59 pm
Subject: [PSES] Application of the definitions of the word "hazard"
To: <[email protected]>

With regard to the use of the word "hazard," consider
an equipment supplied from mains.

We would all agree that mains is a hazardous energy
source (or comprises a hazard).

The equipment in question is provided with a suitable
enclosure and fully complies with the applicable
safety standard.

We have a number of definitions for "hazard" from the
various posted messages:

   anything potentially harmful
   potential for an action with adverse outcome
   something that can hurt you or do property damage
   potential source of harm

Question:  Does the mains within the equipment comprise
a hazard?


Rich

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>



-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at 
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to