Dear Richie, To the specific question: Does the mains within the equipment comprise a hazard? The answer is YES. But the most important aspect is the evaluation of the Risk associated with the hazard. The Risk can be "acceptable" or "unacceptable". Can a harm (electrocutation) be generated due to mains? Which is the probability that this harm occurs? These are the questions to which shall answer. The hazards (potential source of harm) due especially to mains are: electrical shock, fire. The key for analysis is the EXPOSURE to the hazard (with other words the accessibility to the hazardous areas). If not exist EXPOSURE to the hazard or the probability to access the hazardous areas is very small, the associated Risk is acceptable.
Best Regards, Steli Steli Loznen, M.Sc., SM-IEEE I.T.L (Product Testing) Ltd. Q.A & Certification Manager Convener IEC/TC62/SC62A/MT29 1, Bat Sheva St., P.O.Box 87 LOD 71100, ISRAEL Phone:+972-8-9186100 int.203 Fax:+972-8-9153101 Mobile:+972-54-7245794 e-mail: [email protected] www.itl.co.il -----Original Message----- From: Richard Nute [mailto:[email protected]] Sent: Tuesday, November 02, 2010 1:59 AM To: [email protected] Subject: [PSES] Application of the definitions of the word "hazard" With regard to the use of the word "hazard," consider an equipment supplied from mains. We would all agree that mains is a hazardous energy source (or comprises a hazard). The equipment in question is provided with a suitable enclosure and fully complies with the applicable safety standard. We have a number of definitions for "hazard" from the various posted messages: anything potentially harmful potential for an action with adverse outcome something that can hurt you or do property damage potential source of harm Question: Does the mains within the equipment comprise a hazard? Rich - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>