HI Grace,

EN61000-4-3 is being referenced by others too. We completed a 200 v/m version
of EN61000-4-3 from 1 GHz to 18 GHz for the US Coast Guard.

Sincerely,

Derek Walton
L F Research

On 9/2/2010 1:36 PM, Mark Gandler wrote: 

        Grace, 
        there are some service providers specs, for example Comcast, which 
requires
RI up to 6Ghz. 
        Mark
        
        > Date: Thu, 2 Sep 2010 07:27:10 -0400
        > Subject: Radiated Immunity Frequency Range
        > From: [email protected]
        > To: [email protected]
        > 
        > Dear Members,
        > 
        > Is there any product standard(s) requiring frequency above 1GHz for
        > radiated immunity test? The latest 61000-4-3 basic standard does
        > mention test frequency above 1GHz (up to 6GHz).
        > 
        > Thank you and look forward to hearing from you.
        > 
        > Best regards,
        > Grace
        > 
        > -
        > ----------------------------------------------------------------
        > This message is from the IEEE Product Safety Engineering Society 
emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]> <mailto:[email protected]> 
        > 
        > All emc-pstc postings are archived and searchable on the web at:
        > http://www.ieeecommunities.org/emc-pstc
        > Graphics (in well-used formats), large files, etc. can be posted to 
that
URL.
        > 
        > Website: http://www.ieee-pses.org/
        > Instructions: http://listserv.ieee.org/request/user-guide.html
        > List rules: http://www.ieee-pses.org/listrules.html
        > 
        > For help, send mail to the list administrators:
        > Scott Douglas <[email protected]> <mailto:[email protected]> 
        > Mike Cantwell <[email protected]> <mailto:[email protected]> 
        > 
        > For policy questions, send mail to:
        > Jim Bacher: <[email protected]> <mailto:[email protected]> 
        > David Heald: <[email protected]> <mailto:[email protected]> 
        
        -
        ----------------------------------------------------------------
        This message is from the IEEE Product Safety Engineering Society 
emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>
        
        All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
        Graphics (in well-used formats), large files, etc. can be posted to 
that URL. 

        Website: http://www.ieee-pses.org/
        Instructions: http://listserv.ieee.org/request/user-guide.html
        List rules: http://www.ieee-pses.org/listrules.html 

        For help, send mail to the list administrators:
        Scott Douglas <[email protected]>
        Mike Cantwell <[email protected]> 

        For policy questions, send mail to:
        Jim Bacher <[email protected]>
        David Heald <[email protected]> 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to