Hi Grace, There are a few standards I know of that require immunity to radiated frequencies above 1GHz. Some of them up to 2GHz and some up to 2.4GHz.
Best Regards, John Grace Lin <[email protected]> Sent by: [email protected] 09/02/2010 07:27 AM To [email protected] cc Subject Radiated Immunity Frequency Range Dear Members, Is there any product standard(s) requiring frequency above 1GHz for radiated immunity test? The latest 61000-4-3 basic standard does mention test frequency above 1GHz (up to 6GHz). Thank you and look forward to hearing from you. Best regards, Grace - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher <[email protected]> David Heald <[email protected]>