List Members,
 
Thanks for all the great replies! 

Would it make sense to see if the end product can pass safety with the non-LPS
power supply?
 
Is the the LPS clause just a CB scheme requirement or is it required for NRTL
approval also?
 
Best regards,
 
Christine Rodham

Christine Rodham <[email protected]> wrote:

        Hi List Members,
         
        We have a vendor that provides us a unit that uses an external power 
supply (
90- 240VAC)
        The power supply is labeled LPS after the model number which means: 
Limited
Voltage Power Supply.
         
        They recently changed vendors to another power supply with the EXACT 
same
rating Except it was not marked as a LIMITED voltage power supply.
         
        Our supplier says this is not a compliance / safety issue because both
supplies are recognized by UL and have the same voltage and current rating.
         
        So the $64,0000 dollar question is can you use a non- LPS in place of a 
LPS
if they have the same rating?
         
        Thanks in advance,
         
        Thank you in advance!
         
        Christine Rodham
        
        -
        ----------------------------------------------------------------
        This message is from the IEEE Product Safety Engineering Society 
emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>
        
        All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
        Graphics (in well-used formats), large files, etc. can be posted to 
that URL. 
        Website: http://www.ieee-pses.org/
        Instructions: http://listserv.ieee.org/request/user-guide.html
        List rules: http://www.ieee-pses.org/listrules.html 
        For help, send mail to the list administrators:
        Scott Douglas <[email protected]>
        Mike Cantwell <[email protected]> 
        For policy questions, send mail to:
        Jim Bacher <[email protected]>
        David Heald <[email protected]> 


-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to