Hello Neven – Actually I have seen the exact opposite. A conductive floor
with a removable ferrite insert for
immunity.!

Best Regards
Charles Grasso



 

________________________________

From: [email protected] [mailto:[email protected]] On Behalf Of
[email protected]
Sent: Friday, April 30, 2010 12:35 PM
To: [email protected]
Subject: conductive cloth or plate over ferrite floor-patch question

 

Dear EMC-PSTC-ers,

 

Has anyone used semi-anechoic chambers with permanently installed ferrite
tiles in the floor between the antenna and the DUT for radiated-immunity and
with a (re)movable conductive cover for the emission tests.

 

I would love to make it work if possible, because it would make it so much
easier to move and store the thin sheet metal or wire-mesh than moving the
ferrite panels in and out for the immunity tests. Perhaps Laird Flectron
copper-cloth might work,

 

http://www.lairdtech.com/Products/EMI-S
lutions/Specialty-EMI-Solutions/Metallized-Fabric/
<http://www.lairdtech.com/Products/EMI-
olutions/Specialty-EMI-Solutions/Metallized-Fabric/> 

 

We can have ferrites installed in a compact semi-anechoic chamber (3m test
distance) flush with the rest of the GND-plane/floor, but I am not sure if
there is a good way to put a sheet of metal (or a copper wire mesh/cloth) over
it, overlap and make a reliable contact with the GND plane around the
perimeter of the ferrites.  Perhaps with an overlap of at least 6” (15cm) 
with the rest of the GND-plane, using a bunch of magnets around the perimeter
to tie it to the GND plane. Long-term reliability is also my consideration. I
appreciate if you have any experience you are willing to share.

 

Thanks, Neven

 

-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 

-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to