Dear Readers, Indeed the AC is a corrigendum.
The same question I asked in another newsgroup and the opposite opinion was given. So its unclear and I decided to contact the CEN - European Committee for Standardization. They replied with this answer: <<< The AC stands for Amending Corrigendum. Starting January 2011, CENELEC corrigenda shall be cited in the "Official Journal" - considering there was no separate document for these CENELEC corrigenda in the past, it was proposed to indicate them where any, but these shall be found in the amendment of the document itself. No consolidated version will be issued for including a corrigendum. Therefore, two documents will exist separately. In the light of this, you might declare this AC:2011 also on your EC DoC declaration of conformity. But please do check this also with your National Electrotechnical Committee in the Netherlands, the National Electrotechnical Committee. >>> So we will declare the AC:xxxx on our EC DoC's Best regards Jan Mobers -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Knighten, Jim L Sent: vrijdag 8 februari 2013 19:37 To: John Woodgate; [email protected] Subject: RE: [PSES] EC Declaration of Conformity with standards and Amendments Good answer! __________________________ James L. Knighten, Ph.D. EMC Engineer Teradata Corporation 17095 Via Del Campo San Diego, CA 92127 858-485-2537 - phone 858-485-3788 - fax (unattended) -----Original Message----- From: John Woodgate [mailto:[email protected]] Sent: Friday, February 08, 2013 4:58 AM To: [email protected] Subject: Re: [PSES] EC Declaration of Conformity with standards and Amendments In message <[email protected]>, dated Fri, 8 Feb 2013, "Mobers Jan (ST-VS/EAP1.4-NL)" <[email protected]> writes: >A question came up for the EC DoC. The applicable standards with >version / year need to be mentioned. > >But what about the some times applicable amendments of the standards so >called AC:xxxxx. Acs are not amendments, which are designated An (e.g. A2), for 'native' CENELEC standards or amendments prepared by IEC, or Ann (e.g. A13), for amendments by CENELEC of IEC standards. ACs do not have to be quoted in DoCs. They are corrigenda. -- OOO - Own Opinions Only. See www.jmwa.demon.co.uk Analogue is the limiting case of digital, with infinite sampling rate and number of bits. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>