OK, I’ll admit it. I actually added a flashing red light outside my shielded 
chamber door to indicate high-power RF within the chamber. I controlled it by 
simply plugging in an extension cord to the switched outlet on the rear of my 
big RF power amplifier. There had been no requests from safety or insurance 
people; no, I did this all on my own.

 

See, the RF chamber looked so high-tech cool, with all the blue pyramidal 
absorbers and shiny copper tabletop, that management had my lab as a regular 
stop on the “Executive Tour Route.” This was one of those pony shows where, 
when the execs wanted to impress somebody about how high-tech we were, they 
would take them on a walking tour of selected engineering areas. Honest to God, 
once I put that red strobe light in there, I found my petite cash vouchers got 
processed faster and my annual budget seemed to get less trimming. A totally 
excellent return on investment!

 

Ed Price
WB6WSN
Chula Vista, CA USA



 

From: McInturff, Gary [mailto:[email protected]] 
Sent: Friday, January 10, 2014 8:26 AM
To: [email protected]
Subject: Re: [PSES] Risk Assessments and mitigation for EMC chambers

 

Yea I can hardly get more than 4 cats on one of them. J

 

Gary

No animals were hurt in writing this email.

From: IBM Ken [mailto:[email protected]] 
Sent: Friday, January 10, 2014 7:36 AM
To: [email protected]
Subject: Re: [PSES] Risk Assessments and mitigation for EMC chambers

 

My guess is because a microwave is a much smaller volume; not likely to have a 
human inside it when activated.

 

On Fri, Jan 10, 2014 at 9:13 AM, Sundstrom, Michael 
<[email protected]> wrote:

>From a RF Health and Safety point of view, why is a microwave oven allowed 
>with just an interlock on the door and not allowed for a RF enclosure for EMC?
 Human Exposure Limit will not apply if no human is in RF chamber when RF is on.

 Michael Sundstrom
OHD TREQ Dallas
Electronic Lab Analyst EMC Lead
(214) 579 6312 <tel:%28214%29%20579%206312>   office
(940) 390 3644 <tel:%28940%29%20390%203644>   cell
マイク
KB5UKT


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to