I once spent some time at a Southern California lab that built their own damped sinewave circuit only to have an assessor forbid its use because it couldn't be calibrated.

Next;  NIST traceable connectors?

Cortland Richmond


On 3/3/2014 1:18 PM, Pat Lawler wrote:

All,

I need to calibrate our Schaffer NSG2050/PNW2055 surge generator. Two cal houses have 'no bid', and I'm waiting for Teseq to reply.

Any suggestions for facilities in (or near) California?

Pat



-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion 
list. To post a message to the list, send your e-mail to <[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to