Don¹t know what requirement/limit you are testing to, but a limit that is flat below 500 kHz at a level near 2 amps is wrong.
Ken Javor Phone: (256) 650-5261 From: Richard Jones <[email protected]> Reply-To: Richard Jones <[email protected]> Date: Thu, 4 May 2017 09:34:43 -0400 To: <[email protected]> Subject: Re: [PSES] RF CS High Current Test Level Thanks Ken, That's the first piece of the puzzle covered, so still looking for 10KHz-400KHz and above 10MHz. Not sure if Fischer have a full solution for this but will ring them back to see :-) Does anyone know of other vendors who may be able to help? Rich On Wed, May 3, 2017 at 6:10 PM, Ken Javor <[email protected]> wrote: > FCC (Fischer Custom Communications) makes a very large clamp for the purpose > you cite. > > http://www.fischercc.com/products/f-040128-1008-1a/ > > Although they don¹t show a data sheet, you can derive from the max input power > and insertion loss that it¹s capable of injecting 2 amps. But only between > roughly 400 kHz to 10 MHz. > > Ken Javor > Phone: (256) 650-5261 <tel:(256)%20650-5261> > > > > > From: Richard Jones <[email protected]> > Reply-To: Richard Jones <[email protected]> > Date: Wed, 3 May 2017 17:33:10 -0400 > To: <[email protected]> > Subject: [PSES] RF CS High Current Test Level > > > Hi Folks > > Does anyone have experience generating 1.7A CW (10KHz - 400MHz) using Bulk > Current Injection? > > Wondering how people have achieved it, is there a BCI on the market able to > sustain this level "off the shelf" or a vendor who custom builds them? > > A possible alternative was to use multiple BCI's and a Power Splitter, but I > can see this problematic at higher frequencies due to wavelength/phase etc > > I realise that you would need separate BCI's, splitting the test into > frequency bands as no one BCI could do it all > > Thanks for any help provided > > Rich > - > ---------------------------------------------------------------- > > This message is from the IEEE Product Safety Engineering Society emc-pstc > discussion list. To post a message to the list, send your e-mail to > <[email protected]> > > All emc-pstc postings are archived and searchable on the web at: > http://www.ieee-pses.org/emc-pstc.html > > Attachments are not permitted but the IEEE PSES Online Communities site at > http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used > formats), large files, etc. > > Website: http://www.ieee-pses.org/ > Instructions: http://www.ieee-pses.org/list.html (including how to > unsubscribe) <http://www.ieee-pses.org/list.html> > List rules: http://www.ieee-pses.org/listrules.html > > For help, send mail to the list administrators: > Scott Douglas <[email protected]> > Mike Cantwell <[email protected]> > > For policy questions, send mail to: > Jim Bacher <[email protected]> > David Heald <[email protected]> > > - > ---------------------------------------------------------------- > > This message is from the IEEE Product Safety Engineering Society emc-pstc > discussion list. To post a message to the list, send your e-mail to > <[email protected]> > > All emc-pstc postings are archived and searchable on the web at: > http://www.ieee-pses.org/emc-pstc.html > > Attachments are not permitted but the IEEE PSES Online Communities site at > http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used > formats), large files, etc. > > Website: http://www.ieee-pses.org/ > Instructions: http://www.ieee-pses.org/list.html (including how to > unsubscribe) <http://www.ieee-pses.org/list.html> > List rules: http://www.ieee-pses.org/listrules.html > > For help, send mail to the list administrators: > Scott Douglas <[email protected]> > Mike Cantwell <[email protected]> > > For policy questions, send mail to: > Jim Bacher <[email protected]> > David Heald <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) <http://www.ieee-pses.org/list.html> List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher <[email protected]> David Heald <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>