Hello All:

 

Aside from surge tolerance during normal type testing, are there any
regulatory requirements regarding the placement of MOVs from line to ground
on an AC mains input port?

 

I seem to recall that some countries or standards are concerned about
potential hazards associated with MOVs developing high leakage current, over
time, in response to repeated surge events.  I've seen circuits where a GDT
was added in series with the MOV, and I believe this had something to do
with concerns about MOV leakage current.

 

I've also seen MOVs offered for sale that are packaged in a way that
physically couples them to a thermally-activated one-time fuse.  This
implies a concern with the MOV becoming leaky over time and overheating.

 

While I am familiar with the potential failure mechanism of MOVs developing
high leakage current over time, I cannot point to any published safety
standard that imposes any construction requirements that attempt to protect
against this failure mode.  I thought I remembered seeing something on this
topic many years ago in a UK standard, but that was a long time ago, prior
to harmonization of the IEC 60950 series.

 

 

Thanks,

 

Joe Randolph

Telecom Design Consultant

Randolph Telecom, Inc.

781-721-2848 (USA)

[email protected] <mailto:[email protected]> 

http://www.randolph-telecom.com

 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to