Thank you kindly, John and Larry-

I explored ETSI portal as you recommended and found both guidance document and 
draft standard.  Applying receiver requirements to this system should be 
enlightening, to say the least. :)

Chet Summers


From: John Woodgate [mailto:[email protected]]
Sent: Tuesday, July 10, 2018 2:14 AM
To: [email protected]
Subject: Re: [PSES] ETSI EN 302 066-2 & the RED


Note the change of title and the switch from part 2 of a multi-part standard 
(302 066-2) to a single standard (302 066).

John Woodgate OOO-Own Opinions Only

J M Woodgate and Associates 
www.woodjohn.uk<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.woodjohn.uk&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=gVWNFydTvbekx2OCkJHcPzahu85Lm9I6EbQny7n4eXY&e=>

Rayleigh, Essex UK
On 2018-07-10 02:20, Larry K. Stillings wrote:
Hi Chet,

ETSI did publish EN 302 066 V2.1.1 (2017-01) for application under the RED, and 
contains receiver requirements as specified in TS 103 361 V1.1.1 (2016-03) 
Clause 9.

Why it was not published as a harmonized standard under the RED is a good 
question and I assume only a handful of people actually know why. My educated 
guess is because the Commission determined that the standard did not properly 
address or meet the spirit of the receiver requirements as defined in the RED.

A new versions of the standard is in the final draft stage as of June 20, 2018. 
That may be tracked at the following link

https://portal.etsi.org/webapp/workProgram/Report_Schedule.asp?WKI_ID=53489<https://urldefense.proofpoint.com/v2/url?u=https-3A__portal.etsi.org_webapp_workProgram_Report-5FSchedule.asp-3FWKI-5FID-3D53489&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=ZL8NNFCi5JJmN-KaSaHyImp_jFSLGDmUcbyiqWDAoQE&e=>

Considering how specialized GPR technology is and containing only a handful of 
manufacturers across the entire world, I don't know how much support ETSI has 
had in developing the new standards under the RED and thus the delays in 
getting an acceptable standard developed.

Yes technically that means a Notified Body must be used to address the receiver 
requirements.

Larry Stillings
Compliance Worldwide, Inc.



-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]<mailto:[email protected]>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.ieee-2Dpses.org_emc-2Dpstc.html&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=v5lJ4-CmoFR4LRYeViIyHH0oZftTCLTpMfeMzKN-H2o&e=>

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/<https://urldefense.proofpoint.com/v2/url?u=http-3A__product-2Dcompliance.oc.ieee.org_&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=0RNodbNePOAmomzC9OLth9v59LfBZ-c6YvlXdulXqjY&e=>
 can be used for graphics (in well-used formats), large files, etc.

Website: 
http://www.ieee-pses.org/<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.ieee-2Dpses.org_&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=5DqY0VYiuWWCs8PdgTaQdFvMJohCSrO0RiMlmykJHLE&e=>
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.ieee-2Dpses.org_list.html&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=hHTWY92tJTCXz3MfoPbTvGeMJfk_fZsDV6ajD7UOiQk&e=>
List rules: 
http://www.ieee-pses.org/listrules.html<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.ieee-2Dpses.org_listrules.html&d=DwMD-g&c=G4BpsyPyB19LB50bn2swXw&r=uQYjlohUH2VwYVcMCZDVOGnwYsWulCG18FqsT19OrFM&m=3tETgEJBQN37BML8Qhe8JKRrntdlr2mioCcznMKO3Uw&s=CEZGAGwbvY0M9at2EyUXfCZdzB7QeQwNglvcFsSG2e4&e=>

For help, send mail to the list administrators:
Scott Douglas <[email protected]<mailto:[email protected]>>
Mike Cantwell <[email protected]<mailto:[email protected]>>

For policy questions, send mail to:
Jim Bacher <[email protected]<mailto:[email protected]>>
David Heald <[email protected]<mailto:[email protected]>>

This email and any files transmitted with it from Charles Machine Works are 
confidential and intended solely for the use of the individual or entity to 
which they are addressed.

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to