Hi Steve:

 

VW-1 is roughly equivalent to V-1 except applies to wire.

 

Richard

Bend, Oregon

 

From: Stephen Clarke [U3C] <step...@unit3compliance.co.uk> 
Sent: Monday, October 30, 2023 8:50 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [PSES] UL1007 vs VW-1 Flammability ratings

 

Hello Experts

 

I have a battery box that has wiring to UL1007. I can see that UL1007 has a
vertical flame test requirement.

 

How dose this compare with UL VW-1 ?

 

Regards

 

Steve Clarke

Test Engineer

 

Unit 3 Compliance Ltd

EMC : Electrical Safety : Environmental & Vibration : CE & UKCA :
Consultancy

 

www.unit3compliance.co.uk <http://www.unit3compliance.co.uk/>  |
step...@unit3compliance.co.uk <mailto:step...@unit3compliance.co.uk>  |
+44(0)1274 911747

2 Wellington Business Park, New Lane, Bradford, BD4 8AL

Registered in England and Wales # 10574298


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at:
https://www.mail-archive.com/emc-pstc@listserv.ieee.org/

Website:  https://ewh.ieee.org/soc/pses/
Instructions:  https://ewh.ieee.org/soc/pses/list.html (including how to 
unsubscribe)
List rules: https://ewh.ieee.org/soc/pses/listrules.html

For help, send mail to the list administrators:
Mike Sherman at: msherma...@comcast.net
Rick Linford at: linf...@ieee.org

For policy questions, send mail to:
Jim Bacher:  <j.bac...@ieee.org>
_________________________________________________
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

Reply via email to