Jon Elson wrote:

> Look on eBay for "super Vexta" drivers.  Not all of them can do 
> step/direction, which I think they call "two pulse", vs. what 
> they call "one pulse", which is CW and CCW step lines. 
> Actually, it is pretty easy to convert for this, or maybe EMC
> can now generate CW/CCW step pulses.  

EMC's software step generator "stepgen" can do CW and CCW step
pulses.  That is step type 1, which we call "up/down".  (Normal
step/dir is step type 0.)

Regards,

John Kasunich

-------------------------------------------------------------------------