So as not to let this thread die off with no outcome reported, I did get the toolchanger running again by using %IW instead of %W for the tool prep number.
One issue here is that the "Vars" button doesn't show these new variables. Probably a third window is needed after "bit vars" and "internal word vars", "I/O word vars" should be displayed. Just a thought here, not ultra critical. I could certainly assign an %IW to a % W to display it if it was really necessary. Also, other than the source code itself, is there documentation on the classicladder file format? I'm especially interested in the 10 x 6 arrays of "0-0-0/0" type data. I ask because I've had trouble in the past manipulating the ladder logic using the GUI and it would be easier to just directly edit this file. In one case I couldn't delete a vertical connector bar and editing the .clp file was the workaround I used. Thanks, Matt ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users