Andy Pugh wrote:
> 2010/1/8 Flying Electron <[email protected]>:
>
>   
>> The best I can think of so far is to have the gcode turn on one of the
>> digital output pins using M64 and then having the hal multiplex the two
>> parallel port pins into the probe pin, but maybe there is an easier way
>> that won't waste one of the four digital output pins.
>>     
>
> Wire the probes in series?
>   
One of the probes is electrically noisy and untrustworthy when the 
machine is operating, the probe is only used during a calibration 
routine with most of the machine turned off.  But if EMC2 is no longer 
limited to only 4 digital outs, I have no problem using the mux 
component with a M64 line switching the mux between the two probes.
>   
>>   Is the number of
>> digital output pins controllable by gcode hardcoded, or can it be
>> increased through a setting somewhere?
>>     
>
> You can change it (the 2.3.0 release notes say so)
> http://wiki.linuxcnc.org/cgi-bin/emcinfo.pl?action=browse&diff=3&id=Released
>
> I read that it was an INI parameter a few days ago, but I can't recall
> where (or more importantly, what)
>
>   
Thanks!  I can look through the docs to find out where the setting is.

------------------------------------------------------------------------------