On 10 November 2010 18:51, Peter Cauchy <[email protected]> wrote:

> I have picked up a pair of slo-syn ss2000-md7 drivers, and following the
>  docs, hooked them up.  The only problem I am having is they will not
>  change direction.

How do you have the signals connected? It looks a lot like my drive
which requires +5V (**referenced to p-port Gnd**) on the OPTO
terminal, and then the P-Port pins are active-low. (set invert=true in
stepconf)

I think I had a situation where the step signals were AC-coupled
enough to work, but not the direction pins.

You can probably get a handy +5V relative to logic ground from a USB port.

You should be able to leave the AWO and RDCE pins unconnected.

-- 