On 11/03/2011 8:14 PM, Brian May wrote:
> This is kind of off the subject but may be useful in future releases.
>
> On haas machines they have a parameter called grid offset for each axis. 
> Basically it is a parameter that will "offset" the index pulse. This way you 
> can control where your machine zeros without having to fool with the encoders.
>
>    
EMC2 has the "HOME_OFFSET" parameter, that moves the home position to
an arbitrary distance from the home switch or home switch-plus-index-pulse
location.  But, on the dual gantry setup, the two sides need to be kept 
coordinated
at all times, so the homing needs to be done in a synchronized manner.

Jon

------------------------------------------------------------------------------