Can single phase be used on a three phase filter?  The reason I ask is because 
I am rebuilding my lathe so it can be used on both single and three phase.

Thanks,
Clint Washburn                         


On Jan 21, 2013, at 2:37 AM, andy pugh <[email protected]> wrote:

> On 21 January 2013 09:21, Mike Cinquino <[email protected]> wrote:
> 
>> Has anyone seen this before? I
>> know VFD's are noisy devices. Looking for any advice to quickly eliminate
>> the problem.
> 
> You probably need an input filter on the VFD. They appear to send
> noise back down the power supply cables.
> Something like:
> http://www.ebay.co.uk/itm/170127787597
> ("RASMI" may be a good search term)
> 
> A common-mode ferrite ring on the motor cables (at the drive end) is
> also a good idea, but I think that the input filter is the big-hitter.
> 
> -- 
> atp
> If you can't fix it, you don't own it.
> http://www.ifixit.com/Manifesto
> 
> ------------------------------------------------------------------------------
> Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
> MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
> with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
> MVPs and experts. SALE $99.99 this month only -- learn more at:
> http://p.sf.net/sfu/learnmore_122412
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users

------------------------------------------------------------------------------
Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
MVPs and experts. SALE $99.99 this month only -- learn more at:
http://p.sf.net/sfu/learnmore_122412
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to