On 01/21/2013 03:02 PM, Clint Washburn wrote:
> Can single phase be used on a three phase filter?  The reason I ask is 
> because I am rebuilding my lathe so it can be used on both single and three 
> phase.
>
> Thanks,
> Clint Washburn
>
>
> On Jan 21, 2013, at 2:37 AM, andy pugh <bodge...@gmail.com> wrote:
>
>> On 21 January 2013 09:21, Mike Cinquino <mcinqu...@gmail.com> wrote:
>>
>>> Has anyone seen this before? I
>>> know VFD's are noisy devices. Looking for any advice to quickly eliminate
>>> the problem.
>> You probably need an input filter on the VFD. They appear to send
>> noise back down the power supply cables.
>> Something like:
>> http://www.ebay.co.uk/itm/170127787597
>> ("RASMI" may be a good search term)
>>
>> A common-mode ferrite ring on the motor cables (at the drive end) is
>> also a good idea, but I think that the input filter is the big-hitter.
>>
>> -- 
>> atp
>> If you can't fix it, you don't own it.
>> http://www.ifixit.com/Manifesto
>>
>> ------------------------------------------------------------------------------
>> Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
>> MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
>> with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
>> MVPs and experts. SALE $99.99 this month only -- learn more at:
>> http://p.sf.net/sfu/learnmore_122412
>> _______________________________________________
>> Emc-users mailing list
>> Emc-users@lists.sourceforge.net
>> https://lists.sourceforge.net/lists/listinfo/emc-users
> ------------------------------------------------------------------------------
> Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
> MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
> with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
> MVPs and experts. SALE $99.99 this month only -- learn more at:
> http://p.sf.net/sfu/learnmore_122412
> _______________________________________________
> Emc-users mailing list
> Emc-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/emc-users
not sure if you canuse 3ph filter with just 1
but am sure
i used 3 pcs of 1 phase Cor-Com (tm)  on 3 ph equipments a lot
so, this scheme should help your needs
regards
tomp

------------------------------------------------------------------------------
Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
MVPs and experts. SALE $99.99 this month only -- learn more at:
http://p.sf.net/sfu/learnmore_122412
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to