On Tue, Nov 18, 2014 at 09:04:18AM -0500, Mark Wendt wrote:

> At X1, the table height is .001" lower than X0.  X2 is .003" lower
> than X0.  X3 is .002 lower.  X4 is .001 lower.  X5 is .002 lower.
> X6 is .003 lower.  X7 is .004 lower.  X8 is .002 lower.  X9 is
> .001 lower.

Not having seen how your fixtures are mounted to this table, this
may or may not be a useful suggestion, but for a similar problem I
have used feeler gauge stock, which is available in .0005"
increments in these small thicknesses.  Like these: