Hello!

I have Jasic 100 A plasma source and Mesa THCAD card (extended to 310V
measuring range). The thing is that there is no dedicated output
signal in plasma source that would provide a feedback of plasma arc
voltage.

I thought that I might connect THCAD inputs directly to plasma torch
and ground leads, but THCAD manual convinced me not to do so - it says
something about "touch-start plasma only", which does not seem to be
the case here.

So far I have received 2 opposite suggestions:
1) attach THCAD inputs to main transformer output _before_ rectifier
input - I was told that rectifier bridge will protect the board from
any HF (when arc is launched);
I would use very small and simple rectifier bridge (1000 V, 2A) to
make the signal from bipolar to unipolar and then try some HAL magic
to smooth out the fluctuations of the reading value;
2) attach THC inputs _after_ rectifier input - I was told that main
transformer output frequency is in several kHz range and that would
bake my rectifier or some other electronics.

I would appreciate any suggestions, where and how to attach THCAD
board to Jasic plasma source, which does not have dedicated output
signal for THC purpose.

Viesturs

------------------------------------------------------------------------------
Dive into the World of Parallel Programming. The Go Parallel Website,
sponsored by Intel and developed in partnership with Slashdot Media, is your
hub for all things parallel software development, from weekly thought
leadership blogs to news, videos, case studies, tutorials and more. Take a
look and join the conversation now. http://goparallel.sourceforge.net/
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users