> As I reported, I have 4 of them coming. The forcibly guided relay for mine arrived today, so I finished assembling the PSU and then drew a schematic of what I ended up with.
I am using the physical relay to ensure that I can't possibly power the system up with the discharge resistor in circuit. So, if the discharge contacts on the relay weld closed, the input SSR can't be energised. I ended up with a 6-pole relay. A 2-pole NO/NC relay would have worked, though. 620R is actually a bit high for the soft-start resistor. It seems about right for the discharge resistor. -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto
PSU - Schematic.pdf
Description: Adobe PDF document
------------------------------------------------------------------------------
_______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users