On Mon, Jan 25, 2016, at 02:17 PM, Gene Heskett wrote:


> Even unloaded, the slippage is usually north of 20 rpm & quite visible.  

Guess that depends on the motor.

Modern industrial size (1HP and up) three-phase high efficiency induction
motors often have rated speeds of 1780 or 1785 RPM, four-pole 60Hz.

That means that slip at full load is 15 or 20 RPM.  Slip is fairly linear with
load, so a 10HP motor spinning nothing but its own cooling fans can easily
have less than 1 RPM of slip.


-- 
  John Kasunich