On 02/16/2016 06:46 AM, Bertho Stultiens wrote:
> The only alternative is to use a level-based micro-switch. That, 
> however, will probably make it less accurate. Especially when you move 
> over it side-ways. The angle of attack is too small with respect to 
> the travel distance. 


I use roller lever switches bought from DigiKey on my CHNC lathe on a 
pass by setup. That lets me have the limit switches past the home and 
not have to worry about crashing the switch. Repeatability was about 
.0003 inches before the Index pulse was implemented, now within a tenth. 
Use a fairly steep ramp and you get better results.

Ed.


------------------------------------------------------------------------------