> Hello Nicklas, > > On 08/17/16 00:40, Nicklas Karlsson wrote: > > I have tried to use voltage to control EDM gap distance but are not sure > > this is the correct method. I found a paper there someone suggested gap > > resistance is a non linear function of gap distance. > the gap resistance is used indirectly.. > first the dielectric constant of the fluid is 'like' a resistor ( untill > a plasma spark is let thru it) > so, the voltage across this resistor can be a measure of the gap distance
I measure voltage in the middle of the plasma sparc and guess this is wrong. I will try time to measure ionization time instead this is also inline with what I have also seen somewhere in scientefic papers. ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users