the previous my mail ... start with "really not....i work for make my owns a new way..." is for reply to Nicklas.
Thanks to Andy for the right link. 2017-09-28 13:48 GMT+02:00 theman whosoldtheworld <bleachk...@gmail.com>: > really not ... i work for make my owns a new way ... actually i make some > work with modbus ... very nice result, but using halui as it is made I have > no access to all command & status bit/info needed. Using axis remote is a > beautiful solution ... for one machine that have a gui. > So in my lost time, I would like to reload a kind of halui-remote, > complete as an interface as "axis" but for machines that do not have a > video interface on the opposite side of the cable.It's for a while that I > try to find the best solution ... in the end I just thought of > halui-remote, which seems to me the most logical thing to use, just like I > do with modbus + halui. All single commands become single bits, all states > become bit, all errors sig.become bit, now i need to figure out how to make > all array error messages. And emcrsh.cc seems the right response to my > questions. > > After these a right choice of bus ... ethernet based have some problem > about disconnect and reconnect event ... a bus over 2 wire as canopen (or > better canopen fd) i think is the better choice. Slow but whithout connect > and disconnect problem. Modbus rs485 is more fast but the necessary reply > delay make it more slow than canopen. Using ethercat or other modern bus is > possible ... but unfortunately the most widespread bus available in > master and slave versions is profinet. > > Ethercat is a good choice but not a real choice for slave side .... other > 2 bus avaiable is powerlink ie and cc-link ie ... cc-link ie for industry > poupose need a certify not so cheap ... powerlink ie is a good tecnical > choice but ... poor number of device with that bus. > > Other solution may be ethernet/ip ... but if tomorrow I would to work > about realtime event is not the best solutions. > > So canopen or canopen fd. Of course Actually i try to use powerlink ie in > realtime mode. But I'm not sure to rely heavily on that bus. > > > bkt > > 2017-09-26 18:59 GMT+02:00 Nicklas Karlsson <nicklas.karlsso...@gmail.com> > : > >> > >Have you seen: >> > >http://linuxcnc.org/docs/2.7/html/man/man1/linuxcncrsh.1.html >> > <http://linuxcnc.org/docs/2.7/html/man/man1/linuxcncrsh.1.html> >> > >> > Yes I know, work but is not the best solution for control several >> machines. >> >> Do you know a better way to do it? >> >> ------------------------------------------------------------ >> ------------------ >> Check out the vibrant tech community on one of the world's most >> engaging tech sites, Slashdot.org! http://sdm.link/slashdot >> _______________________________________________ >> Emc-users mailing list >> Emc-users@lists.sourceforge.net >> https://lists.sourceforge.net/lists/listinfo/emc-users >> > > ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users