Hi, My 48 volt utility vehicle has 6 8V Crown brand deep cycle batteries CR-190, 190 ah at 20 hour rate. The vehicle is in regular use, no deep discharges, and recharged by a three stage DeltaVolt charger.
I have been noticing that after disconnecting the charger and letting the batteries rest 12 hours that 5 out of 6 batteries were 8.510 to 8.577. The other battery was consistently around 8.414 volts. I tried an equalization charge of 7.5 amps constant current. I ran the equalization charge for 8 hours. The battery got warm but did not use much water. After 12 hours off charge, the voltage read 8.3. Did I damage the battery? Did I quit too early? Any suggestions? Thanks Cliff www.ProEV.com -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.evdl.org/private.cgi/ev-evdl.org/attachments/20130319/ad07a26c/attachment.htm> _______________________________________________ UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub http://lists.evdl.org/listinfo.cgi/ev-evdl.org For EV drag racing discussion, please use NEDRA (http://groups.yahoo.com/group/NEDRA)