Hi,

My 48 volt utility vehicle has 6 8V Crown brand deep cycle batteries CR-190, 
190 ah at 20 hour rate. The vehicle is in regular use, no deep discharges, and 
recharged by a three stage DeltaVolt charger.

I have been noticing that after disconnecting the charger and letting the 
batteries rest 12 hours that 5 out of 6 batteries were 8.510 to 8.577. The 
other battery was consistently around 8.414 volts. I tried an equalization 
charge of 7.5 amps constant current. I ran the equalization charge for 8 hours. 
The battery got warm but did not use much water. After 12 hours off charge, the 
voltage read 8.3.

Did I damage the battery? Did I quit too early? Any suggestions?

Thanks

Cliff

www.ProEV.com


-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.evdl.org/private.cgi/ev-evdl.org/attachments/20130319/ad07a26c/attachment.htm>
_______________________________________________
UNSUBSCRIBE: http://www.evdl.org/help/index.html#usub
http://lists.evdl.org/listinfo.cgi/ev-evdl.org
For EV drag racing discussion, please use NEDRA 
(http://groups.yahoo.com/group/NEDRA)

Reply via email to