HI Roger, I am trying to find out if the problem relates to ide only, ot to scsi as well. I have a problem with an ide device ... So, since you didn't post your dev= line, coudl you let me know if you have an ide device or scsi .... Buchan Roger Sherman wrote: > > Tom, sorry to call you out personally, just wanted to let you know I > figured out the dev= portion of the equation. > > OK, this is for the group... > > When I tried to use cdrecord, the following was the output. Does this tell > anyone anything? > > Last chance to quit, starting real write in 1 seconds. > > Waiting for reader process to fill input buffer ... input buffer ready. > cdrecord: Warning: controller returns wrong size for CD write parameter > page. > Performing OPC... > cdrecord: Warning: controller returns wrong size for CD write parameter > page. > Starting new track at sector: 0 > Track 01: 0 of 4 MB written.cdrecord: Input/output error. write_g1: > scsi sen > dcmd: retryable error > CDB: 2A 00 00 00 00 00 00 00 1B 00 > status: 0x2 (CHECK CONDITION) > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 64 00 00 00 > Sense Key: 0x5 Illegal Request, Segment 0 > Sense Code: 0x64 Qual 0x00 (illegal mode for this track) Fru 0x0 > Sense flags: Blk 0 (not valid) > > write track data: error after 0 bytes > Sense Bytes: 70 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00 > Writing time: 5.030s > Fixating... > cdrecord: Input/output error. close track/session: scsi sendcmd: retryable > error > CDB: 5B 00 02 00 00 00 00 00 00 00 > status: 0x2 (CHECK CONDITION) > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 2C 04 00 00 > Sense Key: 0x5 Illegal Request, Segment 0 > Sense Code: 0x2C Qual 0x04 (current program area is empty) Fru 0x0 > Sense flags: Blk 0 (not valid) > cmd finished after 0.000s timeout 480s > Fixating time: 0.005s > cdrecord: Input/output error. mode select g1: scsi sendcmd: retryable > error > CDB: 55 10 00 00 00 00 00 00 10 00 > status: 0x2 (CHECK CONDITION) > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 24 00 00 00 > Sense Key: 0x5 Illegal Request, Segment 0 > Sense Code: 0x24 Qual 0x00 (invalid field in cdb) Fru 0x0 > Sense flags: Blk 0 (not valid) > cmd finished after 0.000s timeout 40s > cdrecord: fifo had 64 puts and 1 gets. > cdrecord: fifo was 0 times empty and 0 times full, min fill was 100%. > > peace, > > Rog > > http://www.slammingrooves.com > Registered Linux user #190719 > > ------------------------------------------------------------------------ > Keep in touch with http://mandrakeforum.com: > Subscribe the "[EMAIL PROTECTED]" mailing list.
Keep in touch with http://mandrakeforum.com: Subscribe the "[EMAIL PROTECTED]" mailing list.