It's IDE...here's the output from -scanbus:

Linux sg driver version: 2.1.39
Using libscgversion 'schily-0.1'
scsibus0:
cdrecord: Warning: controller returns wrong size for CD capabilities page.
        0,0,0      0) 'LG      ' 'CD-RW CED-8042B ' '1.07' Removable
CD-ROM


blah blah..

Hope that helps!

On Mon, 18 Dec 2000, Buchan Milne wrote:

> HI Roger,
> 
> I am trying to find out if the problem relates to ide only, ot to scsi
> as well. I have a problem with an ide device ...
> 
> So, since you didn't post your dev= line, coudl you let me know if you
> have an ide device or scsi ....
> 
> Buchan
> 
> 
> 
> Roger Sherman wrote:
> > 
> > Tom, sorry to call you out personally, just wanted to let you know I
> > figured out the dev= portion of the equation.
> > 
> > OK, this is for the group...
> > 
> > When I tried to use cdrecord, the following was the output. Does this tell
> > anyone anything?
> > 
> > Last chance to quit, starting real write in 1 seconds.
> > 
> > Waiting for reader process to fill input buffer ... input buffer ready.
> 
> > cdrecord: Warning: controller returns wrong size for CD write parameter
> > page.
> > Performing OPC...
> > cdrecord: Warning: controller returns wrong size for CD write parameter
> > page.
> > Starting new track at sector: 0
> > Track 01:   0 of   4 MB written.cdrecord: Input/output error. write_g1:
> > scsi sen
> > dcmd: retryable error
> > CDB:  2A 00 00 00 00 00 00 00 1B 00
> > status: 0x2 (CHECK CONDITION)
> > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 64 00 00 00
> > Sense Key: 0x5 Illegal Request, Segment 0
> > Sense Code: 0x64 Qual 0x00 (illegal mode for this track) Fru 0x0
> > Sense flags: Blk 0 (not valid)
> > 
> > write track data: error after 0 bytes
> > Sense Bytes: 70 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00
> > Writing  time:    5.030s
> > Fixating...
> > cdrecord: Input/output error. close track/session: scsi sendcmd: retryable
> > error
> > CDB:  5B 00 02 00 00 00 00 00 00 00
> > status: 0x2 (CHECK CONDITION)
> > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 2C 04 00 00
> > Sense Key: 0x5 Illegal Request, Segment 0
> > Sense Code: 0x2C Qual 0x04 (current program area is empty) Fru 0x0
> > Sense flags: Blk 0 (not valid)
> > cmd finished after 0.000s timeout 480s
> > Fixating time:    0.005s
> > cdrecord: Input/output error. mode select g1: scsi sendcmd: retryable
> > error
> > CDB:  55 10 00 00 00 00 00 00 10 00
> > status: 0x2 (CHECK CONDITION)
> > Sense Bytes: 70 00 05 00 00 00 00 0A 00 00 00 00 24 00 00 00
> > Sense Key: 0x5 Illegal Request, Segment 0
> > Sense Code: 0x24 Qual 0x00 (invalid field in cdb) Fru 0x0
> > Sense flags: Blk 0 (not valid)
> > cmd finished after 0.000s timeout 40s
> > cdrecord: fifo had 64 puts and 1 gets.
> > cdrecord: fifo was 0 times empty and 0 times full, min fill was 100%.
> > 
> > peace,
> > 
> > Rog
> > 
> > http://www.slammingrooves.com
> > Registered Linux user #190719
> > 
> >   ------------------------------------------------------------------------
> > Keep in touch with http://mandrakeforum.com:
> > Subscribe the "[EMAIL PROTECTED]" mailing list.
> 
> 
> 

-- 

peace,

Rog

http://www.slammingrooves.com
Registered Linux user #190719


Keep in touch with http://mandrakeforum.com: 
Subscribe the "[EMAIL PROTECTED]" mailing list.

Reply via email to