On Thursday 28 Aug 2003 4:13 am, david wrote:
> Anne,
>
>       I am presently running apcupsd, and if I recall, it required
> nothing more than rpm -Uvh acp.....rpm on my 7.2 box. It has been
> running since '01 without a hickup. The trick is to figure out what
> information your APC box will deal out. (Whether it is a "smart"
> APC or not) Then just set (or play around with the UPS type in the
> config to get the maximum amount of info) The type of "cable" and
> the pin assignments are an issue, but there is plenty of info on
> this on the web. Good luck! I'd tell you more, but I haven't had to
> dork with it in years and Altzheimers is taking its toll.
>
Well, I sorted the conf file as well as I could and tried it.  This is 
the log output.

Mon Sep 01 17:35:28 BST 2003  STATFLAG : 0x02010048 Status Flag
Mon Sep 01 17:35:28 BST 2003  END APC  : Mon Sep 01 17:35:28 BST 2003
Mon Sep 01 17:35:48 BST 2003  APC      : 001,019,0516
Mon Sep 01 17:35:48 BST 2003  DATE     : Mon Sep 01 17:09:45 BST 2003
Mon Sep 01 17:35:48 BST 2003  HOSTNAME : anne-linux.lydgate.net
Mon Sep 01 17:35:48 BST 2003  RELEASE  : 3.10.5
Mon Sep 01 17:35:48 BST 2003  VERSION  : 3.10.5 (04 February 2003) 
mandrake
Mon Sep 01 17:35:48 BST 2003  UPSNAME  : backups400
Mon Sep 01 17:35:48 BST 2003  CABLE    : Custom Cable Simple
Mon Sep 01 17:35:48 BST 2003  MODEL    : DUMB UPS Driver
Mon Sep 01 17:35:48 BST 2003  UPSMODE  : Stand Alone
Mon Sep 01 17:35:48 BST 2003  STARTTIME: Mon Sep 01 17:09:35 BST 2003
Mon Sep 01 17:35:48 BST 2003  STATUS   : ONLINE LOWBATT
Mon Sep 01 17:35:48 BST 2003  MBATTCHG : 3 Percent
Mon Sep 01 17:35:48 BST 2003  MINTIMEL : 2 Minutes
Mon Sep 01 17:35:48 BST 2003  MAXTIME  : 60 Seconds
Mon Sep 01 17:35:48 BST 2003  NUMXFERS : 0
Mon Sep 01 17:35:48 BST 2003  TONBATT  : 0 seconds
Mon Sep 01 17:35:48 BST 2003  CUMONBATT: 0 seconds
Mon Sep 01 17:35:48 BST 2003  XOFFBATT : N/A
Mon Sep 01 17:35:48 BST 2003  STATFLAG : 0x02010048 Status Flag
Mon Sep 01 17:35:48 BST 2003  END APC  : Mon Sep 01 17:35:48 BST 2003
Mon Sep 01 17:35:49 BST 2003  apcupsd exiting, signal 15
Mon Sep 01 17:35:49 BST 2003  apcupsd shutdown succeeded

This is a very old ups.  Am I right in thinking that the 
near-immediate shutdown was because there is very little 
charge-ability left in the battery?  I think I am going to have to 
invest in a new one.

Anne
-- 