Stelios Bounanos wrote:

> 
> Select "RSID reception" from the event menu.
> 
> Check "Ignore duplicates" and set a suitable time span.  This will
> ignore successive RSID transmissions for the previously received mode
> and frequency (+/- the RSID precision).  Not essential but recommended.
> 
> Set trigger limit to 0 (no limit) unless there are a lot of RSID
> transmissions on the band.
> 
> Click the button next to "Show alert window" to insert the default text.
> Or click on the button next to "Append to RX text" to get the text that
> inserts a clickable marker in the received text every time the event is
> triggered.  You can customize the text and of course you can have both
> action types.
> 
> Select an appropriate window timeout, e.g. 30s, if using the alert
> window.
> 
> Test the event to see what the alerts do.  If you are ignoring
> duplicates, you will find that subsequent tests will be ignored
> according to the Dup. time.  To get around this you can reselect the
> event from the list at the bottom to redisplay the event -- this resets
> the timeout of the temporary event that is used for testing.  Or you can
> enable duplicate filtering after testing :-)
> 
> Finally click the Add button to register the event.

Where is this Stelios, I have the ID tab on the setup, but where exactly 
are these settings? I must be missing something?

Rick Kunath, k9ao

Reply via email to