The BR-MLX-1GFx24-ML and BR-MLX-1GFx24-X line cards both show as a BR-MLX-1GFx24-X in the CLI since the "-D" functionality is a license instead of actual hardware differences.
This is off a perfectly happy MLXe-8. M1 (left): NI-MLX-MR Management Module Active M2 (right): NI-MLX-MR Management Module Standby (Ready State) F1: NI-X-HSF Switch Fabric Module Active F2: NI-X-HSF Switch Fabric Module Active F3: NI-X-HSF Switch Fabric Module Active S1: BR-MLX-1GFx24-X 24-port 1GbE SFP Module CARD_STATE_UP 24 0024.3897.9800 S2: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.3897.9830 S7: NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21 Module CARD_STATE_UP 48 0024.3897.9920 S8: NI-MLX-1Gx48-T-A 48-port 10/100/1000Base-T MRJ21 Module CARD_STATE_UP 48 0024.3897.9950 rconsole to the card while it's booting up and see what it dumps out in there. They usually give you some kind of hint why they drop into interactive mode. JM On Mon, Aug 20, 2012 at 2:31 PM, Jeroen Wunnink <[email protected]> wrote: > > Looks like a set of MLX management modules combined with an XMR linecard > (-X), that may be your problem. The MLX linecards end on -M at the end. > > You can try removing the linecard from the chassis, then remove the module > <blah> line from your configuration and re-insert it to see if it gets > recognized correctly. > > > ________________________________________ > From: [email protected] > [[email protected]] on behalf of Frederic Jaeckel > [[email protected]] > Sent: Monday, August 20, 2012 8:17 PM > To: [email protected] > Subject: [f-nsp] BR-MLX-1GFx24-X configured as invalid module > > Hej, > > I got these all new modules in completely new MLX4-e chassis and don't > know what the issue is, but the BR-MLX-1GFx24-X modules are always > recognized as invalid and put into interactive mode. I tried upgrading > the devices from IronWare 5.2c to IronWare 5.3b, but this didn't help. > The LP FPGA images, monitor and boot images are all up to date and the > linecard is not being recognized in both 5.2c and 5.3b. Anyone has an > idea why that is? I have 1GE Fiber SFPs in these linecards. > > #sho mod > Module Status Ports Starting MAC > M1 (left): NI-MLX-MR Management Module Active > M2 (right): NI-MLX-MR Management Module Standby (Ready State) > F1: NI-X-HSF Switch Fabric Module Active > F2: NI-X-HSF Switch Fabric Module Active > F3: NI-X-HSF Switch Fabric Module Active > S1: BR-MLX-1GFx24-X 24-port 1GbE SFP Module CARD_STATE_INTERACTIVE 0 > 0024.38a5.4c00 > (S1: Configured as invalid module) > S2: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 > 0024.38a5.4c30 > S3: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 > 0024.38a5.4c60 > S4: > > # sho log > Aug 20 16:33:53:N:Module 1 is reset by mgmt (reason: boot to interactive mode) > Aug 20 16:33:36:N:System: Module was inserted to slot 1 > Aug 20 16:33:25:N:System: Module was removed from slot 1 > > Cheers, > Frederic Jaeckel > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp > > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp