Hello, On Mon, Aug 20, 2012 at 08:17:29PM +0200, Frederic Jaeckel wrote: > Hej, > > I got these all new modules in completely new MLX4-e chassis and don't > know what the issue is, but the BR-MLX-1GFx24-X modules are always > recognized as invalid and put into interactive mode. I tried upgrading > the devices from IronWare 5.2c to IronWare 5.3b, but this didn't help. > The LP FPGA images, monitor and boot images are all up to date and the > linecard is not being recognized in both 5.2c and 5.3b. Anyone has an > idea why that is? I have 1GE Fiber SFPs in these linecards. > > #sho mod > Module Status Ports Starting MAC > M1 (left): NI-MLX-MR Management Module Active > M2 (right): NI-MLX-MR Management Module Standby (Ready State) > F1: NI-X-HSF Switch Fabric Module Active > F2: NI-X-HSF Switch Fabric Module Active > F3: NI-X-HSF Switch Fabric Module Active > S1: BR-MLX-1GFx24-X 24-port 1GbE SFP Module CARD_STATE_INTERACTIVE 0 > 0024.38a5.4c00 > (S1: Configured as invalid module) > S2: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 > 0024.38a5.4c30 > S3: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 > 0024.38a5.4c60 > S4: > > # sho log > Aug 20 16:33:53:N:Module 1 is reset by mgmt (reason: boot to interactive mode) > Aug 20 16:33:36:N:System: Module was inserted to slot 1 > Aug 20 16:33:25:N:System: Module was removed from slot 1
Dear Colleagues, Are there any updates on that issue? I have the same problem with BR-MLX-1GFx24-X-ML card in MLXe-16 chassis: [email protected]#show module Module Status Ports Starting MAC M1 (upper): BR-MLX-MR2-M Management Module Active M2 (lower): F1: NI-X-HSF Switch Fabric Module Active F2: NI-X-HSF Switch Fabric Module Active F3: NI-X-HSF Switch Fabric Module Active F4: S1: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.38a1.c900 S2: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.38a1.c930 S3: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.38a1.c960 S4: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.38a1.c990 S5: NI-MLX-10Gx8-D 8-port 10GbE (D) Module CARD_STATE_UP 8 0024.38a1.c9c0 S6: S7: S8: S9: S10: S11: S12: S13: S14: S15: S16: BR-MLX-1GFx24-X 24-port 1GbE SFP Module CARD_STATE_INTERACTIVE 0 0024.38a1.cbd0 show log: Nov 12 18:54:54:N:System: G1 based module in slot 16 kept interactive - System in Turbo fabric data mode Nov 12 18:54:54:N:Module 16 is reset by mgmt (reason: boot to interactive mode) But according to "MLX Module Compatibility Matrix" document it should work properly both with SFM and hSFM modules and with BR-MLX-MR2-M mgmt. module. But in this document there is no any note about "Turbo" mode. >From other side, http://puck.nether.net/pipermail/foundry-nsp/2012-April/003519.htm claims that "If the system is operating in Turbo mode, standard switch fabric modules (G1) and standard (G1) interface modules are automatically blocked." Thus, in order to get BR-MLX-1GFx24-X-ML card working properly I should disable turbo-mode of hSFM? But what consequences it may have? And what should I do when there is need to use 100G modules? Thanks in advance! -- MINO-RIPE _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp